  ITEM DESCRIPTION

EPever 1500W IPower Pure Sine Wave Inverter 12VDC 24VDC Input 110VAC 120VAC 220VAC 230VAC Output 50HZ 60HZ Off Grid Inverter

 

Overview                                                        

IPower series is a pure sine wave inverter which can convert 12/24VDC to 110/120VAC 220/230VAC 50/60Hz based on full digital and intelligent design. It features high reliability, high efficiency, concise outline, small volume, full protection functions, easy installation and operation. The inverter can be applied in many fields, such as household emergency lighting system, vehicle mounted system and small field power supply, etc.

 

Features

Complete isolation-type inverter technology

Adoption of advanced SPWM technology, pure sine wave output

Dynamic current loop control technology to ensure inverter reliable operation

Wide DC input voltage range

Low output harmonic distortion (THD≤5%)

Optional output voltage and frequency at 110/120VAC,50/60Hz

High conversion efficiency up to 93% to 94%

USB output 5VDC/1A*

RS485 communication port*

Extensive Electronic protection

*Only the model of the USB output port or RS485 port.

 

Functions

201202

 

DC Input Terminal Positive

RS485 communication port

DC input voltage range 

USB output port (5VDC/1A)

DC Input Terminal Negative

AC output switch

Ventilation Fan 

Mode switch

Grounding Terminal

Fault indicator(red)

AC Outlet

Working indicator(green) 

 

(1) Input rated voltage

12V system input voltage range is 10.8~16V;

24V system input voltage range is 21.6~32V.

(2) Fan Ventilation

When the heat sink temperature is higher than 50℃ or internal temperature is higher than 50℃, the fan will turn on automatically.

When the heat sink temperature is lower than 40℃ and internal temperature is lower than 40℃, the fan will turn off automatically.

(3) AC Outlet (optional)

 

3

The output mode can be changed by the mode switch. This mode can be switched online.

When the switch No.1 is on the ON side, output frequency is 60Hz, otherwise is 50Hz.

When the switch No.2 is on the ON side, the output voltage is 230VAC, otherwise is 220VAC.

The same operation 110VAC and 120VAC

NOTE: Both the output frequency and the output voltage change availability after restart the inverter.

WARNING:DO NOT turn ON/OFF the mode switch when the inverter is working.

 

Protection

Protection and recover

Condition

Phenomenon

Parameter

IPower-12

IPower-22

IPower-42

Over voltage protection

and recover

Input Voltage

Ui

Ui>16V

Ui>32V

Ui>64V

Output is OFF

Green indicator fast flashing

Buzzer sounds

Ui≤14.5V

Ui≤29V

Ui≤58V

Green indicator on solid

The output is on

Low voltage protection

and recover

Input Voltage

Ui

Ui<10.8V

Ui<21.6V

Ui<43.2V

Output is OFF

Green indicator slowly flashing

Buzzer sounds

Ui≥12.5V

Ui≥25V

Ui≥50V

Green indicator on solid

The output is on

Over tem. protection

and recover

Tem.(T)

Heat sink T>80℃

or Internal T>60℃

Inverter turns OFF

Heat sink T≤70℃

and Internal T≤50℃

Inverter turns ON

Overload protection

and recover

Output power S

Rated power Pe

S=1.2Pe

Output is OFF after 15min

Red indicator slowly flashing

Buzzer sounds

S=1.5Pe

Output is OFF after 1min

Red indicator slowly flashing

Buzzer sounds

S=1.8Pe

Output is OFF after 10s

Red indicator slowly flashing

Buzzer sounds

S>2Pe(Rated input voltage) 

Output is OFF after 5s

Red indicator slowly flashing

Buzzer sounds

Load short circuit protection

Output is OFF immediately

Red indicator fast flashing

Buzzer sounds

 

Technical Specifications

Model

IP1500-11

IP1500-12

IP1500-21

IP1500-22

Input Rated Voltage

12VDC

24VDC

Input Voltage Range

10.8~16VDC

21.6~32VDC

Input surge voltage

<20V

< 40V

No-load current

<1.0A

< 0.6A

Output Voltage

110VAC(±5%)
120VAC(-7%~+5%)

220VAC(±5%)
230VAC(-7%~+5%)

110VAC(±5%)
120VAC(-7%~+5%)

220VAC(±5%)
230VAC(-7%~+5%)

Output Continuous Power

1200W

Output Power 15 min.

1500W

Instantaneous impact power

2400W

Output way

Single phase

Output Wave

Pure sine wave

Output Frequency

50/60Hz(±0.2%)

Distortion THD

THD≤5%(Resistive load)

Max. Efficiency

93%

93%

94%

94%

Max. USB Output

5VDC/1A

Working environment temperature

-20°C~+45°C

Storage temperature range

-35°C~+70°C

Humidity range

≤95%(N.C.)

Enclosure

IP20

Altitude

<5000m(Derating to operate according to IEC62040 at a height exceeding 1000 m)

Binding post

Φ 10mm

Overall dimension

326.12×231.5×98.5mm

284.7×231.5×98.5mm

Mounting dimension

208×220mm

163×220mm

Mounting hole size

Φ5.5mm

Net weight

3.90kg

 

Notes of installation

Do not expose the inverter to humid, flammable, explosive or dust environment.

Please make sure the air ventilation clearance around the inverter is more than 10cm.

Never install the inverter in a sealed enclosure with flooded batteries.

 

Operation Steps

Step 1: Turn off the switch of inverter

Step 2: Connect the battery (‘+’ terminal with red line, ‘-’with black line). Do not connect them by contraries, or the power inverter will be damaged.

Step 3: Connect the protective grounding to the ground

Step 4: Connect the AC load to the AC outlet

Step 5: Switch on the fuse or breaker. Switch the inverter to ON and then turn on the loads one by one. Check the operation state of both power inverter and loads. ‘Green’ of the Working indicator means the state is normal.

Step 6: If there are different loads, it is suggested that turn on the load with large startup current first, such as television, then turn on the load such as lamp when the inverter works stably.

Step 7: If the Fault indicator is ‘Red’ and the buzzer alarms or no output when you turn on devices, switch off the loads and     power inverter immediately. Check the system by referring to the troubleshooting guide. Turn on the devices again according to the operation methods after the failure is removed.

 

Environmental Parameters

Working Temperature

-20℃~+45℃

Storage Temperature

-35℃~ +70℃

Humidity

< 95%(N.C.)

Enclosure

IP20

Altitude

< 5000 m (Derating to operate according to IEC62040 at a height exceeding 1000 m)

 

 